Product Category


47
>> Signal Conditioning / Isolation
1

● วัด AC Power 1 - 3 phase
● สัญญาณออก 0 - 10 V / 4 - 20 mA
2

The TSA-FIL Module offers isolated signal conversion and filtering of voltage and current signals. Voltage and current inputs can be combined with voltage and current outputs. The desired configuration should bespecifiedwithorder.
3

The TSA-DMS Module offers signal conditioning of strain gauge bridges with 4-wire or 6-wire technology. Standard ranges are 2, 4, 10 mV/V. Manual offset correction can be done with a Zero trimmer. Sensor supply (standard 5 V DC) is isolated, provided by the module. Depending on the base configuration the module has voltage and current outputs.
4

The TSA-Poti Module offers signal conditioning of potentiometers in 3-wire or 5-wire technology with resistances from 350..1000 Ω. Standard ranges are 100, 50, 25 and 12,5 %. Manual offset correction can be done with a Zero trimmer. Sensor supply (standard 5 V DC) is isolated, provided by the module. Depending on the base configuration the module has voltage and current outputs.
5

The TSA-DC Module offers signal conditioning of Shunt sensors or other arbitrary DC and AC sources. Switchable standard ranges are 150 mV, 500 mV, 1 V and 10 V. The input is differential. Depending on the base configuration the module has voltage and current out- puts.
6

1 or 2 analog outputs, plug-in filters 10 Hz..10 kHz (standard), 4-pole Butterworth or Bessel characteristics, supply voltage 24 V DC, DIN rail mounting TS35
7

The TSA-TC Module offers signal conditioning of thermocouples (standard types J, K and T). Linearisation is done by the module. Maximum measurement range (type K) is -100°C to 1200°C. The standard module has a fixed range (-100°C to +100°C, or +200°C, +500°C, +1000°C, +1200°C) plus type to be specified with order. Calibration is done for this range. Optionally up to three switchable ranges are selectable. The CJC is integrated in the connector, cable break is indicated by an LED. Depending on the base configuration the module has voltage and current outputs.
8

The TSA-XX-RMS Modules offer signal conditioning of FIL, DMS (strain gauge), Poti, DC, and ICP ® applications with parallel (True) RMS processing of the output signal. Matching sensor supply is provided by the module. It has two voltage outputs (signal ± 10 V and RMS 0..7.07 V).
9

The TSA-XX-RMS Modules offer signal conditioning of FIL, DMS (strain gauge), Poti, DC, and ICP ® applications with parallel (True) RMS processing of the output signal. Matching sensor supply is provided by the module. It has two voltage outputs (signal ± 10 V and RMS 0..7.07 V).
10

The TSA-IF Module offers isolated pulse forming of signals from in- ductive speed indicators, Hall devices, incremental transducers and other pulse generators. Sensor supply (5 V DC) is isolated, provided by the module. It has a TTL output and optionally an Open Collector output. There is a 2-channel and 3-channel version available.
11

The TSA-Arithmetic Modules offer isolated combination of voltage signals. One of the four basic arithmetic operations as well as power (multiplication with adjacent averaging) are available. Depending on the base configuration the module has voltage and current outputs.
12

The filters are designed for flexible interference suppression of signals. The cut-off frequency of a TSA Module can be easily changed by inserting another filter. Besides the frequency another characteristics can be selected as well. By combination of 2 filters, an 8-pole filter can be created.
13

● Safe galvanic isolation between input / output / auxiliary voltage with reinforced isolation in accordance with DIN EN 61010-1
● Step response T90 40ms
● Output deviation < 0.2% of the limit value
● Overload protection of the current input with automaticallyresetting fuse
● Operating display and status messages via two-colour LED
● Configuration via front DIP switches
● Plug-in terminal strips
● Narrow installation width of 12.5 mm for carrier rail mounting TS 35
14

TV500 isolating signal converter can be used to isolate and convert field signals 0/4..20 mA or 0/2..10 V DC into industry standard signals for process control systems. The ST500 provides a fully floating isolated transmitter supply.
15

TV500 isolating signal converter can be used to isolate and convert field signals 0/4..20 mA or 0/2..10 V DC out of the intrinsically area. The ST500 provides a fully floating isolated transmitter supply.
16

The TV500H brings the function of an isolating signal converter together with a set point adjuster and offers comparator and hold function. This combination offers therefore the possibility, to simulate a measuring value and the easy way to change the sensor without process interruption.
17

Isolating signal converter TV500L can be used to isolate and convert unipolar or bipolar field signals into industry standard unipolar 0/4..20 mA and 0/2..10 V DC or bipolar signals for process control systems. The output characteristic curve is programmable for increasing or decreasing performance.
18

Loop powered signal converter series TV500P are highly compact devices to isolate and adapt standard signals to active inputs of SPC- and DC-systems. The device is loop powered via the 4-20 mA output
19

Loop powered signal isolator TW 500 are highly compact devices to isolate DC-current signals 0(4)..20 mA without power supply. Up to 3 channels are deliverable in one 22.5 mm DIN rail housing.
20

Isolating signal converter TV501 can be used to isolate and convert 0/4..20 mA and 0/2..10 V signals to the hazardous area. The universal design of the in- and outputs and the wide range of supply voltage limits the devices into 2 models.
21

● 1- oder 2-kanalige Ausführung
● Sichere galvanische Trennung zwischen Eingang / Ausgang / Hilfsspannung
● Funktionale Sicherheit bis SIL2 EN61508
● Eingänge für Schaltkontakte, Namur-Initiatoren oder Optokoppler
● Eingänge eigensicher zum Anschluss von Sensoren in den Ex-Zonen 0 und 20
● Gerätemontage in Ex-Zone 2 möglich
● Galvanische Trennung gemäß den Anforderungen für verstärkte Isolierung (EN60664)
● Zuschaltbare Überwachung des Eingangskreises auf Drahtbruch und Kurzschluss
● Relaisausgänge als Schließer oder Wechsler (Wirkung invertierbar)
● Weitbereichsnetzteil oder 24 V DC
● Konfiguration über frontseitige DIP-Schalter
● Steckbare kodierte Klemmleisten
● Gehäusebreite 12,5 oder 22,5mm
● Tragschienenmontage TS35 EN60715
● Betriebsanzeige, Schaltzustands- und Fehleranzeige durch LEDs
22

Isolating switching repeater TS500 can be used for monitoring and controlling digital signals. The input is suitable for switching contact, proximity switch acc. Namur DIN EN 60947-5-6, or passive electronic outputs of other devices. The output can be delivered as relay SPDT or transistor (voltage free).
23

Isolating switching repeater TS500-Ex can be used for monitoring and controlling digital signals out of the hazardous area. The intrinsically safe input is suitable for switching contact, proximity switch according to Namur DIN EN 60947-5-6, or passive electronic outputs of other devices. The devices must be installed out of the Ex-area because only the input is intrinsically safe.
24

Safety barriers of the series 9001 can be used for varied applications in the area of the automation. They allow the intrinsically safe mode of a HART transmitter, actuator, voltage free contact, temperature sensor, DMS, magnet valves, Display... The compact size makes an easy and space saving mounting possible.