Product Category
- 1GHM product
- 2UV Sensor / Amplifier
- 3เครื่องวัดอัตราการไหล
Flowmeter - 4Encoder
- 5Electrical Engineering
- Installation safety testers [1]
- Oscilloscopes [2]
- Multimeters [3]
- Current clamp multimeters [4]
- Voltage testers [5]
- Waveform generators [6]
- Spectrum analyzers [7]
- Cable locators & testers [8]
- Power analyzers [9]
- LCR & component tester [10]
- Analog meters & built-in devices [11]
- Signal level meters [12]
- Electronics data loggers [13]
- Workshop equipment for electronics [14]
- 6UV Meter / Controller
- 7UV Lamp / LED / Laser
- 8เครื่องวิเคราะห์ก๊าซ
Combustible Gas Analyzer - 9เครื่องวัดความชื้นวัสดุแบบติดตั้งระบบดูผ่าน Online / RS-485
- 10เครื่องวัดก๊าซ
Gas Detector-Portable - 11USB Microscope
- 12เครื่องวัดฝุ่น - Air Quality
- 13เครื่องวิเคราะห์การเผาไหม้ก๊าซในรถยนต์
Automotive Micro Bench for CO, CO2 and HC - 14เครื่องวัดและบันทึกข้อมูลขนาดจิ๋ว
Mini Data Logger - 15Sensor วัดระยะ
Ultrasonic Distance Sensor - 16เครื่องมือวัดอุตุนิยมวิทยา
- 17Ultrasonic anemometer
- 18Panel Meter
- 19CMOS Sensor Wide dynamic range
- 20control valves
- 21Sensors(prctec)
- 22รางป้องกันสายเคเบิ้ล
Cable Protectors - 23Power supply
- 24ตัวแปลงสัญญาณไฟฟ้ามาตรฐาน (ZIEHL)
Measuring Transducers- DC Current Voltage [1]
- AC/DC Current-Voltage [2]
- AC - Current - Transducers [3]
- EC - Decharation of Comformity STWQ [4]
- Current Relay For Photovoltaic – systems [5]
- Twilight Switches [6]
- Phase-Monitor Relays Type PS [7]
- Voltage-monitor Relays [8]
- Current-Relays for current-recognition Type STWs [9]
- Electronic Current-Transformers Current-Sensors [10]
- Frequency- and Speed-Relays [11]
- 25เซ็นเซอร์วัดความชื้นน้ำมัน/Dew point
- 26เซนเซอร์วัดความชื้นในน้ำมัน
Oil humidity sensor - 27เครื่องทดสอบแรงดันไฟฟ้า
Voltage Tester - 28ดิจิตัลมัลติมิเตอร์
Digital Multimeter - 29ดิจิตอลแคลมป์มิเตอร์
Digital Clamp Meter - 30Appliance Tester
- 31เครื่องทดสอบความปลอดภัย
Safety Instrument - 32Installation Tester
- 33เครื่องวัดแสงแดดและอุณหภูมิ
light and Temperature Instrument - 34เครื่องมือทดสอบไฟฟ้า
Electrical Tester - 35AC Current Measurements
- 36Surge Protector
- 37Surge Protector_K-surge
- 38LINE/NOISE FILTER
- 39MOV Test - เครื่องวัด/ทดสอบอุปกรณ์ฟ้าผ่า
- 40Hour meter /Timer / Counter
- 41เครื่องวัดไฟฟ้า
- 42เซ็นเซอร์วัดระยะ
Laser distance, Ultrasonic sensor... - 43Solenoid valves
- 44Control Relay
- 45DIS Sensor
- 46Current sensor / Current relay / Voltage sensor
- 47Signal Conditioning / Isolation
- 48เครื่องวัดไฟฟ้าสถิต
Electrostatic field meter - 49Vibration / Shock Measurement
- 50Computer Controlled Measurement Amplifiers
- 51Torque Measurement
- 52Viscometer
เครื่องวัดความหนืด - 53Wireless Sensors
- 54PID Controller
- 55Signal Simulator
- 56HMI Touch Screen & Controller
- 57เครื่องควบคุมการฟักไข่
- 58PROFESSIONAL DATA LOGGER
- 59Water leak detector - เครื่องตรวจจับน้ำรั่วซึม
- 60Microscope - กล้องจุลทรรศน์, กล้องขยาย
- 61เครื่องชั่งอุตสาหกรรม/LAB
- 62Calibration weights - น้ำหนัก-สอบเทียบ
- 63บริการให้เช่าเครื่องมือวัด
- 64ELECTROMAGNETIC FIELD TESTER - เครื่องวัดสนามแม่เหล็กและสนามไฟฟ้า
- 65REFRACTOMETER - เครื่องวัดความหวาน
- 66Leak detector - เครื่องตรวจสอบรอยรั่วซึม
- 67Spectrum Analyzers
- 68Heat detector อุปกรณ์ตรวจจับความร้อน
- 69EV Charger
- 70Meter ห้องเย็น/ตู้แช่แข็ง
- 71Heater อุตสาหกรรม
- 72Premosys
- 73QR Code Reader / Barcode Reader สำหรับอุตสาหกรรมและไลน์ผลิต
- 74บริการงานติดตั้ง
- 75Sensor/Transmitter Ex proof - กันระเบิด
- 76สมัครงาน
- 77ATEK - Linear position sensors
- 78ATEK - Seam detector sensors
- 79ATEK - Draw wire potentiometers
- 80ATEK - Process control devices
- 81ATEK - Laser distance sensor
- 82Fire detector
- 83Download Brochure/Catalog
- 84Monometer-HK Instruments
- 85Differential Pressure Switch-HK
- 86Indoor air quality-HK
- 87Indoor air quality | Siro-HK
- 88วัด Carbon dioxide แบบติดตั้ง-HK
- 89Differential Pressure-HK
(แบบ Electronic) - 90วัดความเร็ว/ปริมาณลมแบบติดตั้ง-HK
(แบบ Hot wire และ DP) - 91Mano/Air flow meter พกพา-HK
- 92SGLUX UV sensor TOCON
- 93SGLUX UV RADIOMETER
- 94UV Dataloger
- 95Spectrometer
50
>>
Computer Controlled Measurement Amplifiers
The DASIM Universal Amplifier offers computer-controlled signal conditioning of manifold sensors. It has 1 DSP per channel. Signal output is with high precision via analog outputs and digitally via Ethernet and CAN. Parameter setting is done with the software DaSoft. Signal filtering can be configured from 3..3000 resp. 6..6000 Hz at 20 resp. 40 kS/s sample rate.
The DASIM CF Amplifier offers computer-controlled signal conditioning of strain gauge bridges and inductive sensors. It has 1 DSP per channel. Signal output is with high precision via analog outputs and digitally via Ethernet and CAN. Parameter setting is done with the software DaSoft. Signal filtering can be configured from 10..1000 Hz.
The SIQUAD Universal Amplifier offers computer-controlled signal conditioning of manifold sensors. It has 1 DSP per channel. Signal output is digital via Ethernet and CAN and optional with high precision via analog outputs. Parameter setting is done with the software DaSoft. Signal filtering can be configured from 3..3000 Hz at 20 kS/s sample rate.
The SIQUAD DMS4 (Strain Gauge) Amplifier offers computer-controlled signal conditioning of strain gauge bridges. It has 1 DSP per unit. Signal output is digital via Ethernet and CAN and optional with high precision via analog outputs. Parameter setting is done with the software DaSoft. Signal filtering can be configured from 3..3000 Hz at 20 kS/s sample rate.
The SIQUAD DC Amplifier offers computer-controlled signal conditioning of voltage or current signals. It has 1 DSP per unit. For high voltage up to 1000 V, a 2-channel version is available. Signal output is digital via Ethernet and CAN and optional with high precision via analog outputs. Parameter setting is done with the software DaSoft. Signal filtering can be configured from 3..3000 Hz at 20 kS/s sample rate.
The SIQUAD DC2HV Amplifier offers computer-controlled signal conditioning of high voltage or current signals. It has 1 DSP per unit. Signal output is digital via Ethernet and CAN and optional with high precision via analog outputs. Parameter setting is done with the software DaSoft. Signal filtering can be configured from 3..3000 Hz at 20 kS/s sample rate. The SIQUAD Power Measurement Amplifier is used to measure electrical power. The input data, Voltage and Current, are measured with 20 kHz per channel. With these results the amplifier computes RMS of voltage and current, frequency, power factor and active and apparent power. For this the amplifier contains a digital signal processor (DSP). The output of the calculated values is available after the first measured period and will be send digitally through Ethernet and CAN.
The SIQUAD Potentiometer Amplifier offers computer-controlled signal conditioning of potentiometers. It has 1 DSP per unit. Signal output is digital via Ethernet and CAN and optional with high precision via analog outputs. Parameter setting is done with the software DaSoft. Signal filtering can be configured from 3..3000 Hz at 20 kS/s sample rate.
The SIQUAD Thermocouple Amplifier offers computercontrolled signal conditioning of thermocouples. It has 1 DSP per unit. Signal output is digital via Ethernet and CAN and optional with high precision via analog outputs. Parameter setting is done with the software DaSoft. Signal filtering can be configured from 3..3000 Hz at 10 kS/s sample rate.
The SIQUAD Pt100 Amplifier offers computer-controlled signal conditioning of RTD sensors. It has 1 DSP per unit. Signal output is digital via Ethernet and CAN and optional with high precision via analog outputs. Parameter setting is done with the software DaSoft. Signal filtering can be configured from 3..3000 Hz at 10 kS/s sample rate.
The SIQUAD ICP4 Amplifier offers computer-controlled signal conditioning of piezo-electric sensors. It has 1 DSP per unit. Signal output is digital via Ethernet and CAN and optional with high precision via analog outputs. Parameter setting is done with the software DaSoft. Signal filtering can be configured from 3..3000 Hz at 20 kS/s sample rate.
The SIQUAD Frequency Amplifier offers computer-controlled signal conditioning of arbitrary periodic frequency signals. Each of the 2 channels has 2 differential tracks with AC coupling and a following 4-step amplifier stage. So signals with amplitudes from 500 mVpp to 100 Vpp can be handled. Each channel has an additional digital input. An isolated sensor supply is integrated. There is 1 DSP per unit. Signal output is digital via Ethernet and CAN and optional with high precision via analog outputs. Parameter setting is done with the software DaSoft.
Characteristics The SIQUAD DIO-8 Plug-in Unit offers computer-controlled signal conditioning of up to 8 digital input signals and drives 8 relay outputs. The inputs are insulated by optocouplers. The relay outputs can be configured per channel by jumpers to make or break. Front panel LEDs indicates switching states of inputs and outputs.
The SIQUAD AO4 Plug-in Unit provides up to 4 analog outputs. The signal level can be set by the parameter setting software or via a LabVIEW application.
The CAN Interface Unit offers synchronous acquisition of CAN messages from a CAN bus. These data are put on the internal high-speed bus and are processed simultaneously with the other measurement data by the central unit. They can be handled further with an appropriate data acquisition software like DAQSoft or DASYLab (by using the DASYLab driver). Parameter setting is done with the software DaSoft. The CAN-Interface can be used with both DASIM and SIQUAD systems.
The Central Unit is the interface between the internal high-speed bus, the Ethernet connection, an RS 232 interface, and the internal RS 485 bus. It is a plug-in unit for the housing and provides the clock for the amplifiers as well as external clocking and synchronization for additional housings resp. chassis. External trigger signals are also administered by the central unit. A remote control can be connected via the remote interface. Parameter setting of the amplifiers is done with the software DaSoft via the Ethernet or RS 232 interface of the central unit
The Measurement Software DAQSoft offers acquisition and visualization of data for DASIM and SIQUAD systems. First parameters of the amplifiers are set with DaSoft. DaSoft provides the system settings and generates an interface file “DDL.int“ with the necessary specifications for data acquisition. DAQSoft takes this information of the “DDL.int“ automatically. The file is always updated with actual data after each communication of DaSoft with the measurement system. If changes were done in the system with DaSoft, it will be automatically recognized by DAQSoft and notified. Therefore it is not possible to measure with wrong parameters.
The DASIM and SIQUAD Amplifiers fit into (standard) 19” chassis and desktop housings. The housings can be tailored to customerspecific needs concerning number of units and power supply. For mobile applications a wide-range power supply is available.
The SIQUAD CAN Compact Module Uni4 offers computer-controlled signal conditioning of various sensors in 1 module. It has 1 DSP per channel. Signal output is digital via CAN. The protocol is CAN 2.0B. Parameter setting is done with the software DaSoft via a USB-to-CAN interface. Signal filtering can be configured from 3..3000 Hz at 20 kS/s sample rate.
The SIQUAD CAN Compact Modules offer computer-controlled signal conditioning of various sensors. There are a universal of sensor-speciflc amplifiers available.
The SIQUAD CAN mounting-rail module Uni offers computer-controlled universal signal conditioning of various sensors. There is a 1- or 2-channel version available. It has 1 DSP per channel. Signal output is digital via CAN. Protocol is CAN 2.0B. Parameter setting is done with the software DaSoft via a USB-to-CAN interface. Signal filtering can be configured from 3..3000 Hz at 20 kS/s sample rate.
The SIQUAD CAN Stick offers computer-controlled signal conditioning of various sensors. It has 1 DSP per unit. There are 2 versions depending on the sensor requirements. Signal output is digital via CAN. Protocol is CAN 2.0B. Parameter setting is done with the software DaSoft via a USB-to-CAN interface. Signal filtering can be configured from 3..2000 Hz at 20 kS/s sample rate.
The SIQUAD Ethernet Compact Module Uni offers computer-controlled signal conditioning of various sensors. The universal amplifier is using one separate DSP per channel. Signal output is digital via TCP/IP. Parameter setting is done with the software DaSoft. Signal filtering can be configured from 3..3000 Hz at 20 kS/s sample rate
The SIQUAD Ethernet Compact Modules offer computer-controlled signal conditioning of various sensors. There are sensor-specific amplifiers available with 1 DSP per amplifier unit. Signal output is digital via TCP/IP. Parameter setting is done with the software DaSoft. Signal filtering can be configured from 3..3000 Hz at 20 kS/s sample rate.