Product Category


2
>> UV Sensor / Amplifier  
>> Amplifier   [2]
>>  
7
VOLTCON_MED

Specifications

 

Input solder points Photodiode Anode = positive terminal of the photodiode 
Photodiode Cathode = negative terminal of the photodiode
Power supply = Output terminal solder points A voltage of 5...24V is to be applied between V+ and GND. The resulting output voltage between 0 and 5V is measured between the signal output and GND. The voltage is proportional to the applied photocurrent.
Dimensions W x L x H = 13 x 26 x 8mm
Operating temperature -20...80°C
Storage temperature -40...80°C

 

Datasheet